Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Eng Sci Med ; 47(1): 261-272, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38150058

RESUMO

Diagnostic ultrasound (US) scanners are generally evaluated using proprietary quality assurance (QA) phantoms, but their prohibitively high cost may prevent organizations to perform the necessary tests. This study aimed to develop a low-cost gel wax phantom with targets to determine the lateral and axial resolution and diameter of a hyperechoic target in an US scanner. The acoustic property (AP) of gel wax, which includes the speed of sound (cus), acoustic impedance (Z), and attenuation coefficient (µ), were determined for multiple transducers operating at 2.25, 5, 10, 15, and 30 MHz. These results were compared to the AP of soft tissue. Two polytetrafluoroethylene (PTFE) rectangular frames with holes separated by 5, 10, and 20 mm were constructed. Nylon filaments and stainless-steel disc (SS disc) (diameter = 16.8 mm) were threaded through the frames and suitably placed in gel wax to obtain orthogonal targets in the phantom. The target dimensions obtained from computerized tomography (CT) and US images of the phantom were compared for phantom validation. The average cus=1431.4 m/s, mass density ρ = 0.87 g/cm3, Z = 1.24 MRayls, and µ ranged from 0.7 to 0.98 dB/cm/MHz for gel wax at 22 °C. The US image measurement exhibited a maximum error in determining the diameter of the SS disc, resulting in a value of 18 mm instead of its actual value of 16.8 mm. The phantom volume decreased by 1.8% in 62 weeks. The present phantom is affordable, stable, customizable, and can be used to evaluate diagnostic US scanners across multiple centers.


Assuntos
Tomografia Computadorizada por Raios X , Ultrassom , Ultrassonografia/métodos , Imagens de Fantasmas , Acústica
2.
Phys Eng Sci Med ; 43(4): 1171-1181, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32809141

RESUMO

Materials with acoustic properties similar to soft-tissue are essential as tissue-mimicking materials (TMMs) for diagnostic ultrasound (US). The velocity (cus), acoustic impedance (AI) and attenuation coefficient of US (µ) in a material collectively define its acoustic property. In this work, the acoustic properties of polychloroprene rubber, beeswax, and Carbomer-gel are determined. The pulse-echo technique is used to estimate cus and µ. The product of a sample density (ρ) and cus gives its AI. Using a reference based on the International Commission on Radiation Units and Measurements Report-61, Tissue Substitutes, Phantoms and Computational Modelling in Medical Ultrasound, the results are evaluated. The acceptance criteria are 1.043 ± 0.021 g/cm3 (ρ), 1561 ± 31.22 m/s (cus), 1.63 ± 0.065 MRayls (AI) and µ within 0.5-0.7 dB/cm/MHz. Sample computerized tomography (CT) and US scanning are performed to evaluate their similarities (contrast and speckle pattern) with respective images of the human liver (a clinical soft-tissue). The average errors in measuring cus and µ were 0.14% and 1.2% respectively. From the present findings, acoustic properties of polychloroprene and beeswax are unacceptable. However, the results of Carbomer-gel ρ = 1.03 g/cm3, cus = 1567 m/s, AI = 1.61 MRayls are satisfactory and µ = 0.73 dB/cm/MHz, is higher than the reference (4.3%). Carbomer-gel could produce CT and US images, efficiently mimicking the respective liver images. Carbomer-gel containing 95% water is a low-cost material with a simple formulation. Present results suggest, Carbomer- gel mimics soft-tissue and can be used as a TMM for diagnostic US.


Assuntos
Acústica , Neopreno , Resinas Acrílicas , Humanos , Ultrassonografia , Ceras
3.
J Pediatr Hematol Oncol ; 38(1): e6-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26583622

RESUMO

Congenital anomalies may be associated with Wilms tumor either as isolated anomalies or as part of a congenital malformation syndrome. Nephroblastoma occurring in association with polycystic kidneys is very rare. The optimal surgical management of nephroblastoma in the setting of polycystic kidneys is not defined because of the rarity of this presentation. PHACE syndrome includes posterior fossa anomalies, hemangioma, arterial lesions, cardiac abnormalities/coarctation of aorta, and eye abnormalities. We report a 17-month-old baby with bilateral polycystic kidneys and PHACE syndrome who developed nephroblastoma in the right polycystic kidney which was treated successfully with nephron-sparing partial nephrectomy and chemotherapy.


Assuntos
Coartação Aórtica/complicações , Anormalidades do Olho/complicações , Neoplasias Renais/complicações , Neoplasias Renais/cirurgia , Síndromes Neurocutâneas/complicações , Doenças Renais Policísticas/complicações , Tumor de Wilms/complicações , Tumor de Wilms/cirurgia , Anormalidades Múltiplas/patologia , Feminino , Humanos , Lactente , Neoplasias Renais/patologia , Nefrectomia , Síndrome , Tumor de Wilms/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...